Smart Relay Configuration
Introduction
The SmartRelay offers two basic modes of operation. Stand-alone and Wireless. In the standalone mode, the DIP switches are used as a reference to configure the operation of the module. In wireless mode, the command received from the controlling unit informs the module what to do.
Operational Modes
The modes of operation are detailed below and are activated based on a binary code. This enables different options or modes.
The module has a number of operating modes, ensure that the unit is configured correctly. When not configured correctly, the error indication will flash when the input is activated.
๏ปฟ
Dip Switch Setting | Operation | Description |
|---|---|---|
0000 | No configuration / Test mode |
๏ปฟ |
0001 | Relay on | When the opto input is triggered, the relay will switch on, and then off when the input is released. |
0010 | Relay Pulse | The relay pulses at 500ms intervals. |
0011 | Relay switches from normally open to normally closed | This is the inversion of "Relay on". |
0100 | Relay Pulses, from normally open to normally closed repeatedly. | This is the inversion of "Relay Pulse". |
0101 | Relay Pulse + | TBA |
0110 | TBA | TBA |
0111 | TBA | TBA |
1000 | RF Wireless Mode | This mode usess a wireless module to recieve a signal that actuates the relay. Each module will have a unique ID that is found in the device's packaging. |